Geothermal energy


Geothermal Engineering & Advisory | CRETA Group

Geothermal / Geoscience / Engineering

Energy beneath us.
Possibilities
ahead.

From climate control to power generation, CRETA connects subsurface understanding with the engineering needed to turn geothermal opportunities into viable projects.

Site-led assessmentIntegrated system designMeasured performance
01 / Heating & cooling

Design around the load.
Engineer with the ground.

Ground-coupled systems exchange heat with the subsurface. We assess the demand, ground conditions and operating temperatures together to select a suitable system architecture.

Homes / Villas / Residential developments

Comfort with a considered
energy strategy.

Evaluate geothermal heating and cooling for new developments and retrofits, with attention to comfort, available land, installation access and the lifetime operating profile.

Design focus: load assessment, ground-loop options, heat-pump selection, distribution and controls.
  • Hourly and seasonal heating and cooling demand
  • Horizontal or vertical ground heat exchangers
  • Ground properties and thermal testing where warranted
  • Integration with existing HVAC and hot-water systems
  • Whole-system energy use and lifecycle economics

Ground temperature, geology and annual heat balance govern performance. Heat pumps, pumps, fans and backup systems are selected according to the application; passive cooling is not assumed.

Interactive engineering insight

Where does the heat go?

200 kWHeat removed from the load
50 kWCompressor electricity input
250 kWHeat rejected to the ground

Ground heat rejection = cooling load + compressor input.

Illustrative heat-pump energy balance, not a performance forecast or sizing tool. COP is a user-selected assumption. Ground exchange is assumed to carry the full heat-pump source/sink duty; pumps, fans, auxiliaries, heat recovery and losses are excluded. Real design uses measured conditions and equipment performance data.

02 / Exploration to power generation

Characterise the resource.
Build the development case.

Geothermal development brings together heat, fluid pathways, engineering and project economics. CRETA connects exploration and reservoir evaluation with risk assessment and power-plant design.

Locate the opportunity.
Define what must be tested.

Integrate geological mapping, structural interpretation, geophysics, geochemistry and available well information to develop a conceptual geothermal model.

Scope & outputs

  • Regional screening and prospect ranking
  • Temperature evidence and fluid-pathway interpretation
  • Target definition, data gaps and uncertainty
  • Exploration programme and appraisal-well objectives

Plant capacity and conversion technology follow the resource assessment. Temperature or depth alone does not establish commercially viable power generation.

03 / Oil & gas well repurposing

A well’s original purpose
may not be its last.

Existing wells can offer subsurface access, historical data and installed infrastructure. CRETA evaluates whether depleted or inactive oil and gas assets can support a technically sound geothermal application.

Start with the well’s condition.
Prove the thermal opportunity.
Then select its next use.

Repurposing is assessed case by case. Re-entry, remediation and conversion costs can outweigh the value of the available heat.

Direct heat & heat-pump integration

Assess recoverable heat for nearby buildings, agricultural facilities, thermal networks or suitable processes. Heat pumps may raise the delivery temperature where required.

  • Match source temperature and flow to a real heat demand
  • Consider transport distance, fluid isolation and chemistry
  • Evaluate reinjection, thermal decline and operating energy
Power generation where justified

Screen generation options, including binary cycles, where well deliverability and temperature support a viable net output.

  • Use measured or defensibly corrected temperature data
  • Account for production and reinjection pumping
  • Compare net generation with workover and plant costs
Closed-loop well conversion

Evaluate an isolated downhole heat exchanger where the well geometry and integrity permit it. Heat transfer through the well and surrounding formation can constrain output.

  • Review casing, cement, completion and usable diameter
  • Model thermal resistance and time-dependent heat recovery
  • Assess circulation losses and conversion requirements
Co-produced heat from active fields

For wells still in production, assess heat recovery from produced fluids alongside the existing oil and gas operation.

  • Understand fluid rates, temperatures and separation needs
  • Protect hydrocarbon operations and materials compatibility
  • Evaluate heat use or generation without assuming viability
01 / Asset condition

Completion records, barriers, integrity tests, ownership and access.

02 / Thermal evidence

Temperature profiles, flow history, chemistry and recovery behaviour.

03 / System match

Demand location, conversion options, reinjection and operating limits.

04 / Development case

Workover scope, approvals, lifecycle economics and closure obligations.

Engineering clarity

Questions worth
answering early.

A credible geothermal strategy makes its assumptions explicit. These distinctions shape both the engineering and the commercial case.

Does geothermal cooling require a compressor?
Ground-source heat-pump systems normally use a compressor. Direct ground cooling can reduce or bypass compressor operation only when ground and delivery temperatures allow it; circulation energy still matters. The selected configuration depends on the application.
Can the ground absorb heat indefinitely?
Continuous heat rejection can raise ground temperatures. Long-term design considers thermal response, annual heat balance, exchanger spacing and possible heat recovery or hybrid rejection. This is particularly important for data centres and cooling-dominated climates.
Can every depleted oil or gas well become a geothermal asset?
No. Suitability depends on integrity, temperature, heat-transfer or fluid-delivery potential, nearby demand, permissions and conversion economics. Some wells should be excluded during screening.
Begin with the right questions

What could geothermal
do for your project?

Tell us your application, location and current stage. We can discuss the evidence required, the study scope and the next engineering decision.

malriahy@cretagrp.com

Useful starting information: location, building area, heating/cooling loads, operating schedule and available land.

Opens a draft in your email application. No information is submitted from this page.

CRETA GROUP · Geothermal & Subsurface EngineeringBack to top ↑

Enable JavaScript to explore all application tabs and the heat-balance illustration. Well-repurposing details and direct email contact remain available.